SECTION 4 HSMLT WINDOWS BASED SET-UP PROGRAM REFERENCE Number of Cans in FIFO - Avg.: This is the average number of cans in the FIFO when the machine is running above 800 cpm FIFO Low Corrections Count: This is the number of FIFO faults that have occurred when the average number of cans in the FIFO has dropped below the FIFO Min. A FIFO low fault would be caused by double clocking a can at the “Reject Photo Eye”. This count is retained indefinitely but can be reset by clicking the “Calibrate FIFO” button. FIFO High Corrections Count: This is the number of FIFO faults that have occurred when the average number of cans in the FIFO has exceeded the MIFO Max. A FIFO high fault would be caused by missing a can at the “Reject Photo Eye”. This count is retained indefinitely but can be reset by clicking the “Calibrate FIFO” button. Missed Can Presence Count: This is the number of FIFO faults that have occurred due to missing a can at the “Can Presence” sensor. This count is retained indefinitely but can be reset by clicking the “Calibrate FIFO” button. HSL-LTA/LTS User’s Manual SYSTEMS Electronics Group - 65 -