Download Manual - Richard Martin Lighting
Transcript
MENU SYSTEM : MENU FUNCTIONS 4 Table 4-2: Menu Function Definitions (Continued) Display Definition Purpose Inv Pan Invert Pan Reverses pan action for special focus requirements. Inv Tilt Invert Tilt Lamp Lamp Lamp Hours Lamp Hours Displays total number of lamp operating hours. Lamp Level Lamp Power Level Displays lamp power levels: 1500W, 1200W, or 900W. Lamp OFF Lamp is Off Configures arc luminaire so that lamp will not strike upon power up. Reverses tilt action for special focus requirements. Accesses lamp power-up options, reset and information (Config) or tests Lamp function (Test). Lamp ON Lamp is On Configures arc luminaire so that lamp will strike upon power up. Lum ID Luminaire ID Displays unique luminaire ID number. Magenta Magenta Specifies magenta parameter for manual control (Manual) or testing (Test). Manual Manual Accesses options for luminaire mechanism control by entry of data values. Movement Movement Normal Zoom Mode OFF Off Off Time Display off time Enables or disables pan and tilt movement. Zoom configuration is in normal mode. Turns off a function. Shows the automatic shut-off time for the menu display. OK Okay Indicates calibration has completed and no errors have occurred. OK? Okay? Prompt for pressing [Enter] before an action is executed. ON On Indefinitely Pan Pan Pan/Tilt Pan/Tilt PASS Test Pass Power Lamp Power Power Up Power Up PROG Programming Sets Menu Display to stay on until programmed otherwise (Display) or turns on a function. Specifies pan function for manual control (Manual) or testing (Test). Accesses pan and tilt options for focus swap function, movement enable/disable, manual control and testing. Indicates that a test has passed. Accesses options to turn lamp on or off. Accesses options for lamp power up state. Currently programming the new version of software. Re Cal Recalibrate Reset Default Reset Defaults Recalibrates luminaire. Reset Hours Reset Lamp Hours RUN TEST Run Test Indicates that a mechanism test is in progress. Sensor Sensors Accesses sensor types for diagnostic testing. Status Status/Error Strobe Strobe Resets default system configuration values. Resets lamp hour and strike counters. (For use when new lamp is installed.) Allows scrolling through error list or displays OK if no errors. Specifies strobe function for manual control (Manual) or testing (Test). STST Sensor Test Indicates that a system sensor test is in progress. Studio Zoom Mode Zoom configuration is in quiet mode for studio use. Swap Swap Swaps pan/tilt action for special focus requirements. Test Test Accesses diagnostic tests for internal mechanisms. Tilt Tilt Specifies tilt function for manual control (Manual) or testing (Test). Version Version 02.96 86.000 1 0 Displays current software version date and time (in two pages). 28-June-2007 51