Download Manual - FlowVision GmbH
Transcript
Flow Meter | FC01- Ex TECHNICAL DATA 8.5.2 Transistor outputs (DC switching voltage) Pin selection: Signal name Pin XAH / ERROR emitter 1 - / ERROR collector 2 + / BUSY / PULSE emitter 3 - / BUSY / PULSE collector 4 + Limit Switch 2 emitter 5 - Limit Switch 2 collector 6 + Limit Switch 1 emitter 7 - Limit Switch 1 collector 8 + Voltage level Low level - active: Uce < 0,8 V for IC < 10 mA Uce < 1 V for IC < 100 mA High level - passive: Uce < 48 V Uce max. leakage current ≤ 25 µA Reverse polarity protection: yes - Imax < 1 A Short-circuit protection: yes - Imax < 1 A max = 60 V Resistive load Max. admissible switching capacity: 1.5 W Max. admissible switching current: 150 mA Max. admissible switching voltage: 36 V Inductive load - L < 100 mH (DC voltage - without external safety circuit) Max. admissible switching capacity: 1.5 VA Max. admissible switching current: 40 mA Max. admissible switching voltage: 36 V Capacitive Last - C < 20 µF Max. admissible switching capacity: 1.5 VA Max. admissible switching current: 1.5 A Max. admissible switching voltage: 36 V Insulation voltage: signal contact - central electronic unit 500 V signal contact - signal input 500 V 70 Polarity