Transcript
Installation 4.3 Connecting the off-heat duct The off-heat duct supplied enables a controlled discharge of warmed air, which allows the device to be operated even in confined spaces. The off-heat of the heat exchanger needs to be conducted from the installation space to the outside sideways or downwards in a 10 cm/3.95 in duct. 1 3 2 The supply air side must not be guided by a duct to ensure that the installation space is well ventilated. 2 1 3 1. Supply air, at least ø 10 cm/3,95 in 2. 3. Exhaust gas Exhaust air 1. Sink the screws for the off-heat flange into the holes provided at the air outlet of the EFOY Pro fuel cell. 2. Attach the off-heat bow to the offheat flange. Use the off-heat bow to conduct warm air sideways or downwards. If you do not need the off-heat bow, you can connect the off-heat tube directly to the off-heat flange. Page 23