5-8 Restart Functions Free-run Stop Function (FRS) Activating the free-run stop (FRS) function shuts off the Inverter output, letting the motor go into free-run status. This function is effective when you stop the motor using the mechanical brake such as an electromagnetic. Note that an overcurrent trip may occur if the mechanical brake forces the motor to stop during Inverter output. Allocate "11: FRS" to any Multi-function Input Selections (C001 to C007). The motor performs a free-run stop while the FRS terminal is turned ON. When the FRS terminal is turned ON and then OFF, the Inverter will restart after an elapse of the time set in Restart Standby Time (b003). However, the Inverter will not restart if RUN Command Selection is set to "Digital Operator" (A002 = 02). To restart the Inverter, input the RUN command. As the Inverter output method at restart, 0 Hz restart, frequency matching restart or frequency pull-in restart can be selected by Free-run Stop Selection (b088). (Examples 1, 2, 3) When Frequency Matching Lower Limit Frequency Setting (b007) is set, the Inverter will restart at 0 Hz if a frequency below the frequency set here is detected at the time of frequency matching restart. The setting of this function will be applied to the FRS terminal, and also when the Inverter is reset from free-run status. 5 Functions Parameter No. b088 Free-run Stop Selection Data Description 00 0 Hz restart (example 1) 01 Frequency matching restart (example 2) 02 Frequency pull-in restart (example 3) Default setting Unit 00 − b003 Restart Standby Time 0.3 to 100.0 Time until restart 1.0 s b007 Frequency Matching Lower Limit Frequency Setting 0.00 to 400.0 (1000.) Setting of frequency matching level 0.00 Hz b028 Frequency Pull-in Restart Level 0.20 × Rated current to 2.00 × Rated current Current limit level at frequency pull-in restart INV rated current A b029 Frequency Pull-in Restart Parameter 0.1 to 3000. 0.50 s b030 Starting Frequency at Frequency Pull-in Restart Selection 00 − − − C001 to C007 5-103 Function name Multi-function Input Selection 00 Frequency at interruption 01 Maximum frequency 02 Set frequency 11 FRS: Free-run stop SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
Related documents
SYSDRIVE JX Series
Read and Understand this Manual
Omron 3G3MX AC Drive User Manual - Innovative-IDM
USER`S MANUAL
cn
Inverter Serie NE-S1 Manuale di base
Inversor serie NE-S1 Manual básico - Hitachi Industrial Components
RX USER`S MANUAL
WJ200 Quick Reference Guide NT3251X
MX2 Series EtherCAT Communication Unit User`s Manual
Manuel de base - Hitachi Industrial Components & Equipment Group
Inverter serie WJ200 Guida rapida di consultazione