Download FEBRUARY 2006 £3.80

Transcript
measurements we got the feeling that
something was not right with this
amplifier. Perhaps a component was
defective? However, we could quickly
rule that one out, since the other channel provided similar measurement
results. What was going on here?
Back to the designer
Consulting with the designer of the circuit caused a reaction of disbelief over
our measurements. He also asked us to
assess the amplifier acoustically. The
latter turned out – no surprise here – to
be rather bad. During the listening test
we also kept an eye on the speaker
signal with an oscilloscope, and even
then the crossover distortion in the
bridge halves was visible.
We were also asked to confirm that the
duty cycle of the amplifier equalled
50% without an input signal. This was
correct and can be determined from
the oscilloscope picture that clearly
shows that the output is at half supply
voltage. Next item on the checklist:
was the power supply capable
enough? That could surely not be the
problem, we had used a big lab power
supply that is capable of delivering at
least 40 A.
After reporting our results we were
asked to make a few more measurements on the amplifier, such as power
supply voltage, differential input
amplifier, the triangle amplitude and
(again) the symmetrical output signal
between the bridge halves. These
were all correct, except for the output
signal, as we had established earlier.
Figure 4. The integrated control signal that drives the HIP4082 is not quite
sinusoidal because of the negative feedback that is present.
2/2006 - elektor electronics
The designer also suggested overshoot
in the output filter as a possible cause
for the strong distortion, but in our
opinion the output filter could never
cause distortion this bad.
We were not making much progress
here! According to the designer everything was in order (all the samples that
he had built gave him comparable
measuring results), but according to us
something didn’t smell right.
More measurements
After we had spent all this time on this
amplifier we could not just abandon it
and we decided to investigate further
to determine the cause of the amplifier
behaviour. The preceding measurements gave the impression that the
input amplifier, the internal regulated
power supply and the PWM-modulator
were all largely correct. But there was
still no explanation for the severely distorted output signal from the bridge
halves. To check the signals to the
driver IC for the MOSFETs, we measured those via a small low-pass filter
(10 kΩ/100 pF).
The signal (Figure 4) did not show any
asymmetry on either input to the
HIP4082 (the noise is the remainder of
the PWM-modulation). This signal is
not quite sinusoidal because the negative feedback in the output stage
compensates and this results in a deviating curve.
This led is to the conclusion that the
driver IC, a HIP4082 from Intersil, had
to be responsible for the problems in
the output stage.
Figure 5. After a few modifications, the output signal from our test circuit
finally started to resemble the input signal.
53