Fluid thioglycollate media (FTGM) test
Materials: Test tubes with autoclavable screw caps, 1-liter flask with 500 milliliters of filtered
seawater, 14.5 grams of thioglycollate media (FTGM), scale, hot plate, 1-liter beaker, gloves,
autoclave, 1-ml sterile pipette
Note: FTGM is used as a qualitative test to detect the presence of bacteria in algae culture media.
Procedure:
1) Assemble materials. Wash hands with antibacterial soap and warm water.
2) Weigh 14.5 grams of FTGM media
3) Mix the FTGM with 500 ml of filtered seawater
4) Place on a hot plate and boil until the mixture turns from a brown color to a clear yellow
5) Pour 10 ml of the mixture into test tubes filling until they are about half-full
6) Secure the lids to the test tubes and autoclave for 30 minutes at 121 degrees Celsius.
7) When cool, remove from the autoclave and place in storage on shelf.
Testing algae cultures for bacteria contamination
1) Using sterile technique and individual sterile Pasteur pipette, draw 0.25 ml from each algae
culture to be tested.
2) Immediately place the sample of algae culture media in an individual test tube of FTGM and
discard pipette. Use individual pipette for each sample. Label test tubes appropriately.
3) Place test tubes on a shelf in the dark or cover to prevent light from reaching the tubes.
4) Incubate for 24 hours and observe tubes. Look for a cloudy appearance in the tubes which
indicates that bacteria are present in the sampled culture. Continue incubation for 24 hours
more and use for comparison purposes.
5) This is a qualitative test and does not indicate the extent of contamination or species of
bacteria. However, intuition can be used to compare cloudiness to give a relative comparison
between and among tested cultures.