5.4.3 Counter latch operation It is often desirable to read the value of a counter without disturbing the count in progress. Usually the method used is the counter latch command method which allows the user to read the latched count value of the selected counter. The 8254 supports the counter latch operation in two ways. The first way is to set the RW1 and RW0 to be (0,0) which latches the count of the selected counter in a 16-bit hold register. The second approach is by performing a latch operation under the read-back command by setting the SC1 and SC0 to be (1,1) and CNT = 0. This method has the advantage of operating several counters at the same time. A subsequent read operation on the selected counter will retrieve the held value. 24 PCL-836 User's Manual