Transcript
Note Pod reset occurs upon power-up, programming process, or watchdog time-out. Command Functions The following paragraphs give details of the command functions, describe what the commands cause, and give examples. Please note that all commands have an acknowledgement response. You must wait for a response from a command before sending another command. Write to DAC Channel An=xxx0 Writes xxx to DAC n. Set polarity and gain using the AC command. Example: Program the Analog output number 4 to half-scale (zero volts bipolar or half scale unipolar) SEND: A4=8000[CR] RECEIVE: [CR] Load Buffer for DAC n An,iiii=xxx0 Writes xxx to DAC n buffer [iiii]. Example: Program buffer for DAC 1 to a simple stair step SEND: A1,0000=0000[CR] RECEIVE: [CR] SEND: A1,0001=8000[CR] RECEIVE: [CR] SEND: A1,0002=FFF0[CR] RECEIVE: [CR] SEND: A1,0003=8000[CR] RECEIVE: [CR] Read Buffer from DAC n An,iii=? Reads from buffer (0 <= n <= 7, 0 <= iiii <= 800h). Example: Read buffer entry number 2 for DAC 1 SEND: A1,0002=?[CR] RECEIVE: FFF0[CR] Start Buffered DAC Output on DAC n An=GOGOGO Writes buffer to DAC n at a timebase rate. Example: Begin Buffer writing on DAC 5 SEND: A5=GOGOGO[CR] Manual MRDAG12-8H.Bc1 Page 3-3