Dithering Meters
Included in the dithering section are two meters. A DC offset meter lets you view the
amount of DC reduction that is being performed on the program material, while a bit meter
provides you a view of the bit activity of the digital signal.
DC Offset Meter
When the DC Offset Filter is On, the DC Offset meter shows the level of the DC (in dB) that
is being removed. You can right click on the meter to set options including turning it on or
off, and enabling the peak hold or not.
Like other meters in Ozone, left-clicking on the DC offset meter will reset the peak hold and
clear its history.
Bit Meter
This can be an invaluable resource for monitoring the digital activity of your program
material, including viewing whether the full range of bits (dynamic range) is being used, the
output word length, faulty A/D converters, sub-par plugin processing (detecting a plugin
that's only processing at 16 bit, using fixed integer math, etc.), etc.
This meter monitors the state of bits in a digital signal.
The inner two columns show the real time activity of the bits of audio, for the left and right
channels. The outer two columns remember the real time activity in a sort of "peak hold"
way. If the inner columns toggle a bit (i.e. "light up") the outer columns will show that bit
as being used.