ECE 477 Final Report
The possibility of IR interference is also an issue. It is possible that due to a bug, an IR command
could be continuously sent out over an IR blaster. This could be a waste of power and a nuisance
if a particular command was being sent out (e.g. TV being turned on and off in rapid succession
or IR LED constantly on). It could also interfere with operation of other IR remote devices if
signals got crossed. If an IR output was stuck on it should not interfere with operation of other IR
devices however, as the control of components is based on the timing of rising and falling edges
in the IR signals.
There is also concern of physical damage to the product. In a user's household, there could be
children or animals that could easily spill food on the device or cause the device to fall, resulting
in damage possibly beyond repair. There are no moving parts inside the device, so physical
shock should not cause any extensive damage to the circuitry. However, if the case became
dented or broken, this could cause damage to the internal components. There should at least be
an error message displayed on the LCD if the device gets into a 'soft' failure mode and is unable
to be operated. There is also a heartbeat signal on the board that flashes a green LED in normal
operation. If this light is stuck on or off, then there is an error. Responsible action should also be
taken in regards to case design to ensure that it is robust enough to at least handle a minor fall,
and that the internal components are isolated from the outside to prevent any foreign material
from getting in the case and causing a problem.
The most concern for potential harm to the user would be a power circuit failure. This could
cause fires or shock to the user if handled improperly. The highest potential for this kind of
failure would be in the event of a short circuit. This could occur if traces were bridged if liquid is
spilled into the device or some other conductive material somehow came in contact with the
PCB. To prevent any foreign material from getting into the device, the casing should provide
adequate protection for the internal components. Short circuits could essentially be turned into a
minor issue if proper fuses are used. Lastly, proper ventilation for the device should allow for
any excess amount of heat to be dispersed so that the functionality of the device is not
jeopardized. If for some reason the device ends up in a confined space, there could be heat
23