Download Design Report - matthew.barga
Transcript
ECE 477 Final Report The possibility of IR interference is also an issue. It is possible that due to a bug, an IR command could be continuously sent out over an IR blaster. This could be a waste of power and a nuisance if a particular command was being sent out (e.g. TV being turned on and off in rapid succession or IR LED constantly on). It could also interfere with operation of other IR remote devices if signals got crossed. If an IR output was stuck on it should not interfere with operation of other IR devices however, as the control of components is based on the timing of rising and falling edges in the IR signals. There is also concern of physical damage to the product. In a user's household, there could be children or animals that could easily spill food on the device or cause the device to fall, resulting in damage possibly beyond repair. There are no moving parts inside the device, so physical shock should not cause any extensive damage to the circuitry. However, if the case became dented or broken, this could cause damage to the internal components. There should at least be an error message displayed on the LCD if the device gets into a 'soft' failure mode and is unable to be operated. There is also a heartbeat signal on the board that flashes a green LED in normal operation. If this light is stuck on or off, then there is an error. Responsible action should also be taken in regards to case design to ensure that it is robust enough to at least handle a minor fall, and that the internal components are isolated from the outside to prevent any foreign material from getting in the case and causing a problem. The most concern for potential harm to the user would be a power circuit failure. This could cause fires or shock to the user if handled improperly. The highest potential for this kind of failure would be in the event of a short circuit. This could occur if traces were bridged if liquid is spilled into the device or some other conductive material somehow came in contact with the PCB. To prevent any foreign material from getting into the device, the casing should provide adequate protection for the internal components. Short circuits could essentially be turned into a minor issue if proper fuses are used. Lastly, proper ventilation for the device should allow for any excess amount of heat to be dispersed so that the functionality of the device is not jeopardized. If for some reason the device ends up in a confined space, there could be heat 23