Download 1 Fire Detection Control Panels Series BC06

Transcript
284 Chapter 27 Optical and Acoustic Devices, ADM Series 700/200/XP95
Long lifespan of strobe due to the use of LEDs
Integrated dual-isolator
Integrated detector base
2 decadic rotary switches for setting the sounder/strobe address from 01 to 99
Different base versions available
Specifications
Operating voltage
Current consumption from loop
Sound level (detector mounted)
Examples (at 24V):
Continuous tone 660Hz
DIN tone 1200-500Hz
Slow Whoop tone 500-1200Hz
Flash frequency
Ambient temperature
Relative humidity
Dimensions Ø × H
Colour
Weight
Approval
Cross-references
355166
supply through the loop voltage
typ. 450µA (sounder and strobe off)
max. 4.3mA (low sound level)
max. 5.6mA (medium sound level)
max. 9.2mA (high sound level)
typ. 70dB(A) / 1m distance (low sound level)
typ. 79dB(A) / 1m distance (medium sound level)
typ. 87dB(A) / 1m distance (high sound level)
max. 95dB(A) / 1m distance (high sound level)
typ. 6.6mA at 90dB(A) / 1m distance
typ. 7.8mA at 89dB(A) / 1m distance
typ. 7.9mA at 86dB(A) / 1m distance
1Hz
-25°C to +70°C
10 - 96% (no condensation)
112 × 42 (mm) (without detector, incl. Base LPBW)
red / white
136g
VdS G206076
Page
Art.No.
Name Type
299
300
301
36
34
302
359040
359043
359045
214037
214021
359050
Base Sounder & Strobe/IP24/White LPBW
Base Sounder & Strobe/IP44/White SDBW
Lid for Sounder/200/10pcs. IBS-LIDPW-10X
Loop Interface LIF128-1
Loop Interface LIF64-1
Mounting Plate for Sounder/200/5pcs. DBSPW/5
Sounder-Strobe/200/Ivory/Red/Multitone IBSST-DR-P01
The addressable sounder with strobe (red cap) is accommodated in a round cream-coloured plastic housing and is prepared for indoor surface mounting. The integrated base is
suitable for accommodation of fire detectors Series 200. The unit is mounted on a base
for signalling devices (not provided). The componentry is actuated using System
Sensor/200 protocol and is powered via the ADM loop. The sounder is always activated together with the strobe.
Depending on the parameter setup of the Fire Detection Control Panel Series BC216 and the system condition, the panel
can activate the sounder with tone A or B. The tone type of tones A and B is set via a DIL switch, with selection out of 32
combinations. The sound level is adjustable in 3 steps, but depends also on the chosen tone type. The power consumption is dependent on the tone type and the adjusted sound level.
Features
32 different tone type combinations selectable via DIL switch (e.g., continuous tone
660Hz, DIN 33 404 tone 1200 - 500Hz, Slow Whoop tone 500 - 1200Hz)
Sound level adjustable in 3 steps (low-medium-high)
Long lifespan of strobe due to the use of LEDs
Low power consumption
Integrated detector base
2 decadic rotary switches for setting the sounder/strobe address from 01 to 99
Different base versions available
B
01 / E09301EB.SAM
/0930-01/0100