Download 1 Fire Detection Control Panels Series BC06
Transcript
284 Chapter 27 Optical and Acoustic Devices, ADM Series 700/200/XP95 Long lifespan of strobe due to the use of LEDs Integrated dual-isolator Integrated detector base 2 decadic rotary switches for setting the sounder/strobe address from 01 to 99 Different base versions available Specifications Operating voltage Current consumption from loop Sound level (detector mounted) Examples (at 24V): Continuous tone 660Hz DIN tone 1200-500Hz Slow Whoop tone 500-1200Hz Flash frequency Ambient temperature Relative humidity Dimensions Ø × H Colour Weight Approval Cross-references 355166 supply through the loop voltage typ. 450µA (sounder and strobe off) max. 4.3mA (low sound level) max. 5.6mA (medium sound level) max. 9.2mA (high sound level) typ. 70dB(A) / 1m distance (low sound level) typ. 79dB(A) / 1m distance (medium sound level) typ. 87dB(A) / 1m distance (high sound level) max. 95dB(A) / 1m distance (high sound level) typ. 6.6mA at 90dB(A) / 1m distance typ. 7.8mA at 89dB(A) / 1m distance typ. 7.9mA at 86dB(A) / 1m distance 1Hz -25°C to +70°C 10 - 96% (no condensation) 112 × 42 (mm) (without detector, incl. Base LPBW) red / white 136g VdS G206076 Page Art.No. Name Type 299 300 301 36 34 302 359040 359043 359045 214037 214021 359050 Base Sounder & Strobe/IP24/White LPBW Base Sounder & Strobe/IP44/White SDBW Lid for Sounder/200/10pcs. IBS-LIDPW-10X Loop Interface LIF128-1 Loop Interface LIF64-1 Mounting Plate for Sounder/200/5pcs. DBSPW/5 Sounder-Strobe/200/Ivory/Red/Multitone IBSST-DR-P01 The addressable sounder with strobe (red cap) is accommodated in a round cream-coloured plastic housing and is prepared for indoor surface mounting. The integrated base is suitable for accommodation of fire detectors Series 200. The unit is mounted on a base for signalling devices (not provided). The componentry is actuated using System Sensor/200 protocol and is powered via the ADM loop. The sounder is always activated together with the strobe. Depending on the parameter setup of the Fire Detection Control Panel Series BC216 and the system condition, the panel can activate the sounder with tone A or B. The tone type of tones A and B is set via a DIL switch, with selection out of 32 combinations. The sound level is adjustable in 3 steps, but depends also on the chosen tone type. The power consumption is dependent on the tone type and the adjusted sound level. Features 32 different tone type combinations selectable via DIL switch (e.g., continuous tone 660Hz, DIN 33 404 tone 1200 - 500Hz, Slow Whoop tone 500 - 1200Hz) Sound level adjustable in 3 steps (low-medium-high) Long lifespan of strobe due to the use of LEDs Low power consumption Integrated detector base 2 decadic rotary switches for setting the sounder/strobe address from 01 to 99 Different base versions available B 01 / E09301EB.SAM /0930-01/0100