Download Signature Flow Meter

Transcript
Signature™ Flow Meter
Indicating Silica Gel
Material Safety Data Sheet
Identity (Trade Name as Used on Label)
Manufacturer
:
MSDS Number* :
MULTISORB TECHNOLOGIES, INC.
M75
(formerly Multiform Desiccants, Inc.)
Address:
CAS Number* :
325 Harlem Road
Buffalo, NY 14224
Phone Number (For Information):
716/824-8900
Emergency Phone
716/824-8900
Date Prepared:
July 6, 2000
G.E. McKedy
Prepared By* :
Number:
Section 1 - Material Identification and Information
Components - Chemical Name & Common Names
(Hazardous Components 1% or greater; Carcinogens 0.1% or
greater)
%*
OSHA
PEL
ACGIH
TLV
Silica Gel SiO2
98.0
Cobalt Chloride
>2.0
6mg/m
(total dust)
3
0.05mg/m
(TWA cobalt
metal dust &
fume)
3
OTHER LIMITS
RECOMMENDE
D
3
10mg/m
(total dust)
3
.05mg/m
(Cobalt, TWA)
Non-Hazardous Ingredients
TOTAL
100
Section 2 - Physical/Chemical Characteristics
Boiling
N/A
Point
Vapor Pressure
N/A
(mm Hg and Temperature
Vapor
N/A
Density
(Air =1)
Solubility
Insoluble, but will adsorb moisture.
in Water
Appearance
Purple crystals, no odor.
and Odor
Specific Gravity
(H20 = 1)
Melting
Point
Evaporation Rate
(__________=1)
Water
Reactive
2.1
N/A
N/A
Not reactive, but will adsorb moisture.
Section 3 - Fire and Explosion Hazard Data
Flash Point and
Auto-Ignition
Flammability Limits in
LEL
UEL
N/A
N/A
N/A
Methods Used
Temperature
Air % by Volume
Extinguisher
Dry chemical, carbon dioxide and foam can be used.
Media
Special Fire
Water will generate heat due to the silica gel which will adsorb water and liberate heat.
Fighting Procedures
Unusual Fire and
When exposed to water, the silica gel can get hot enough to reach the boiling point of water. Flooding with
Explosion Hazards
water will reduce the temperature to safe limits.
Section 4 - Reactivity Hazard Data
Conditions
STABILITY
Moisture and high humidity environments.
To Avoid
Stable
Unstable
Incompatibility
Water.
(Materials to Avoid)
Hazardous
Carbon dioxide, carbon monoxide, water
Decomposition
Products
Conditions
HAZARDOUS POLYMERIZATION
None.
To Avoid
May Occur
*Optional
C-2