Download ELECTRIC BUILT-IN OVENS
Transcript
Hard wiring detail Cabinet construction for your appliance 1. Remove terminal cover plate from rear panel of appliance. For the best integration within a kitchen, install the appliance in a standard 600mm wide cupboard that gives a flush fit with the surrounding cupboard fronts as shown in Fig. A. A recess of 20 mm is ideal. 2. Fit wires through hole in cover plate and make connections to terminals. 3. Engage wires into plastic clip. Secure plastic clip with two long silver screws (supplied in separate bag). With the exception of pyrolytic ovens, the appliance can also be installed using a proud fit to the surrounding cupboard as shown in Fig. B. 4. Replace cover plate onto rear panel. 15mm 553mm WARNING CAUTION 8mm min clearance For all Pyrolytic clean oven models, the oven must be installed as a flush fit to the surrounding cupboards and the “Infill panel” MUST not exceed 100mm in length. This ensures a 16mm gap is maintained between the cabinet and oven side to prevent the cupboard overheating. Fig. A 16mm Flush Fit 568mm Infill panel A 100mm max for Pyro oven 20mm Cupboard door Fig. B Oven 600mm 16mm 568mm Second active wire only required (optional) for multi-phase products Plastic clips Infill panel Proud Fit 100mm max for Pyro oven Plastic clip securing points Cupboard door Oven 600mm INSTALLATION 43