Download TX6100 User Manual
Transcript
MetroX 12-Port QSFP InfiniBand Long Haul System Hardware User Manual Rev 1.1 4 Extracting and Inserting FRUs 4.1 Extracting and Inserting the Power Supply Unit With both power supplies installed in the redundant configuration, either PS unit may be extracted without bringing down the system. Make sure that the PS unit that you are NOT replacing is showing all green, for both the PS unit and status indicators. Figure 26: Fan and PS unit Air Flow Direction OK OK ! ! OK ! Fan Air flow direction PS unit Air flow direction Power supply units have directional air flows similar to the fan module. The Fan module airflow must coincide with the airflow of all of the PS units. If the PS unit airflow direction is different from the fan module airflow direction the switch internal temperature will be affected. Figure 27: Power Supply Unit Extraction OK OK ! ! OK ! Push Here Latch release Mellanox Technologies 41