Download IS23x-MA Digital Stepper Motor
Transcript
CAN-Bus Supply Input Min. All voltages referred to GND_CAN Nominal values † Supply voltage Absolute maximum values, continuous Absolute maximum values, surge (duration ≤ 10mS) † Supply current Normal operation Isolation voltage Between GND and GND_CAN Typ. Max. Units 12 24 VDC -30 +30 VDC -50 +35 V 80 mA 500 VRMS Units 40 Isolated Digital Inputs (ENABLE, LSP, LSN) All voltages referred to GND_IO Logic “LOW” Input voltage Logic “HIGH” Absolute maximum, surge (duration ≤ 1S) Input current Input impedance Logic “HIGH” Typ. Max. -5 0 0.5 12 24 VLOG -12 4 10 25 0.5 Referred to GND_IO 2.5 mA KΩ 0 5 KHz μS 100 0→1→0 or 1→0→1 V +65 Logic “LOW” Input frequency Pulse width † Min. Isolated Digital Outputs (GPO) All voltages referred to GND_IO Min. Typ. Logic “HIGH”; Output crt. = 50mA VLOG-3 VLOG-1 Output voltage † Absolute maximum, continuous Output current Clamp diodes current Logic “HIGH”; Output voltage ≥VLOG-3V VLOG + 0.5V -0.5 50 Max. 0.1 † V 60 Logic “LOW” (leakage current) Output voltage ≤ (-0.5V) or ≥ (VLOG+0.5V); Units -100 +100 0 5 mA Absolute maximum, continuous Output frequency External load 1KΩ to GND_IO Pulse width 0→1→0 or 1→0→1; no external load (5VPP) Short-circuit protection © Technosoft 2007 KHz μS 100 Yes 18 IS23x-MA Technical Reference