5.5 Clearing the Plotter’s Internal Buffer Memory The BUFFER CLEAR function allows you to clear cutting data that has been saved in the plotter’s internal buffer memory. Setting Procedure (1) Consecutively press the F1 F2 (2) F2 (3) FORCE OFFSET MARK CLEAR F2 QUALITY NEXT PAGE key to display the menu below. F3 F4 (BUFFER CLEAR) key to display the menu below. FORCE OFFSET BUFFER CLEAR? YES NO SPEED QUALITY F3 F4 To clear existing data in the internal buffer memory, press the clear the data, press the (4) PEN U/D SELECT PEN SPEED Press the F1 PAUSE key and Press the F4 F2 (YES) key. If you do not wish to (NO) key. PAUSE key to return the plotter to READY status. CAUTION • Only use this function after the plotter has finished receiving all of the data sent from the computer. • If you perform a BUFFER CLEAR operation while the computer is in the process of sending data, the data received in the plotter’s internal buffer memory before the plotter was switched to PAUSE status will be cleared, but the plotter will output any data received after it returns to READY status from PAUSE status. In the latter case, the plotter may suddenly start operation, so be sure to keep hands and other parts of the body away from the pen holder. If you select NO in response to the “BUFFER CLEAR?” prompt, the plotter will resume the operation which you suspended by pressing the PAUSE key. 5–8