4.10 General Commands
General commands allow the reading and setting of various controller parameters.
Description
Command Data Len Data Descriptions
Set LED Display Mode
234 (0xea)
1
LedMode(0~7)
Set Watchdog Time
235 (0xeb)
1
WdTimeTenths(1~239)
Commit Settings
236 (0xec)
0
Load Factory Settings
237 (0xed)
0
Reset as Startup
238 (0xee)
0
Display Version
239 (0xef)
0