Download ASAS (Non-Linear)

Transcript
Loading Data
ASAS (Non-Linear) User Manual
ELEMENT Data
To define the elements to which non-uniform temperature is to be applied. This data must be followed by a list
of nodal temperature values.
E
//elno//
RP
nrep
ielno
RRP
nrrep
iielno
FIN
Parameters
E
: keyword to define element data.
elno
: list of user element numbers to which the non-uniform temperature is applied. (Integer)
RP
: keyword to indicate data generation from the previous / symbol.
nrep
: the number of times the data is to be generated. (Integer)
ielno
: user element number increment to be added each time the data is generated by the RP command.
(Integer)
RRP
: keyword to indicate data generation from the previous // symbol.
nrrep
: the number of times the data is to be generated. (Integer)
iielno
: user element number increment to be added each time the data is generated by the RRP command.
(Integer)
FIN
: keyword to denote the end of set of element definitions.
Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.