CHAPTER 3. OBSERVING WITH SPIRE
repetitions chosen) can also be recovered from a high resolution observation, i.e. improving
the sensitivity to the continuum.
For cases where the signal-to-noise ratio (SNR) for this extracted low resolution spectrum is
not sufficient for the scientific case, the following “High and Low” resolution mode is available:
High and Low Resolution:
Usage and Description: This mode allows to observe a high resolution spectrum as well
as using additional integration time to increase the SNR of the low resolution continuum to
a higher value than would be available from using a high resolution observation on its own.
This mode saves overhead time over doing two separate observations.
The number of high resolution and low resolution scans can di↵er, and will depend on the
required S/N for each resolution. If the number of repetitions for the high and low resolution
parts are nH and nL respectively, then the achieved low resolution continuum sensitivity will
correspond to nH+nL repetitions, because low resolution data can also be extracted from
every high resolution scan.
3.3.2
Pointing Modes
A pointing mode and an image sampling are combined to produce the required sky coverage.
Here the pointing modes are described.
Single Pointing Mode:
Usage and Description: This is used to take spectra of a region covered by the instrument
field of view (20 diameter circle, unvignetted). With one pointing of the telescope only the
field of view of the arrays on the sky is observed.
Raster Pointing Mode:
Usage and Description: This is used to take spectra of a region larger than the field of view
of the instrument (20 diameter circle). The telescope is pointed to various positions making
a hexagonally packed map (see example in Figure 3.14). At each position, spectra are taken
at one or more BSM positions depending on the image sampling chosen (see Section 3.3.3).
The HSpot input parameters are shown in Figure 3.12, right.
Details: The area to be covered determines the number of pointings in the map. The
distances between individual pointings are 11600 along the rows and 11000 between the rows
as shown in Figure 3.14. The number of pointings needed to cover the map is rounded up
to ensure that the whole of the requested area is mapped. The area is by default centred on
the target coordinates, however this can be modified by map centre o↵sets (given in array
coordinates).
Note that for raster maps the target centre does not necessarily correspond to the centre of
the detector array (see Figure 3.14). As the map is not circular and because the orientation
of the array on the sky changes as Herschel moves in its orbit, the actual coverage of the map