Download DAQlink III System User`s Manual
Transcript
4.2.1 Device Acquisition Menu – Standard Menu The Acquisition Menu allows the following selections 1. Gain – This entry sets the pre-amp gain on the DAQlink III. Standard setting for Seismic acquisition is 16 a. Gain =1 maximum input is 3.58 volts peak to peak. b. Gain =16 maximum input is 0.22 volts peak to peak. 2. Sample Rate – This entry allows for different sample rate selection. a. 16 msec – 62.5 samples per second b. 8 msec- 125 samples per second c. 4 msec – 250 samples per second d. 2 msec – 500 samples per second e. 1 msec – 1000 samples per second f. 0.5 msec- 2000 samples per second g. 0.25 msec- 4000 samples per second h. 0.125 msec – 8000 samples per second i. 0.0625 msec – 16000 samples per second j. 0.021 msec – 48000 samples per second 3. Acquisition Time – This entry selects the acquisition time for each acquisition. 4. Active Channels – Select number of active channels 5. Low Cut Filter – When checked will enable the 2Hz low cut filter in the DAQlink III unit 30 User’s Manual