Error Type Poor detection of upper thread Bad jump Bad stitch Cause Inspection & Repair ① Failure of thread detecting roller Disassemble the roller and clean the roller and bush bearing. ② Poor connection & quality of tension adjusting board Check board connection and change the circuit board ① Bad SMPS for jump Change front fuse controller box ② Bad wiring for jump motor Bad jump motor Check wiring and change jump motor ③ Bad connection Check connection ④ Switch failure on tension adjusting board and bad circuit board Change switch and circuit board ① Bad design Correct tape ② Inadequate tension on X-Y belt Adjust tension ③ Foreign substance in X-Y rail Clean the rail ④ Failure of X/Y driver Change circuit board ⑤ Heavy load on frame Reduce speed of main shaft rotation 12-3 , in Reference Check fuse spec 1) 3-phase: , = 250V 15A 2) 1-phase: , = 250V 30A