4.2.1.1.2 EXAMPLE: IRRIGATION BASED ON EXTERNAL CONDITION (STORAGE TANK LEVEL)
FIGURE 26. IRRIGATION BASED ON STORAGE TANK LEVEL
Dry contact 2
4
Dry contact 1
Valve number 4 is used for dam filling. Program 3 will be used to control the dam filling through a 1.4
EXTERNAL CONDITION program. Dry contact 1 (Low Level Sensor) will start program 3 and Dry
contact 2 (High Level Sensor) will stop program 3.
FIGURE 27. IRRIGATION PROGRAM SCREEN – EXAMPLE FOR EXTERNAL CONDITION
DATE : 01-Feb-08
Program:
3
TIME : 08:30:30
IRRIGATION PROGRAM
Priority: 13
Cond.
Start Time
Clock Start
Con. Starts
Min. Time
Max. Time
1
08:00
-ON
00:00
00:00
Valve #
Run Time #
Dosing Prog
004
3
3
Day: 01/01
Dose/Water
1
D
FIGURE 28. IRRIGATION RUN TIME FOR EXTERNAL CONDITION EXAMPLE
6 sec delay
Start
Condition
Input
Stop
Condition
Input
On
Off
6 sec delay
On
On
Off
Off
Irrigation
Program
Version 3.00 JA20111229
Run Time
User Manual – NMC Irrigation
###########