Download FMECA Volume 1: Top Level

Transcript
PASSED FOR PUBLICATION
related
Oxygen
Insufficiency
related
All materials, flows and components in contact Y
with oxygen to have full oxygen assesment
(FMECA V6 Risk 6.10)
Y
Y
0000435
Oxygen
Insufficiency
related
Oxygen injector to be checked during positive
pressure test at startup (FMECA V6 Risk 6.9)
Y
Y
Y
0000434
Oxygen sensors to be calibrated in air (FMECA
V6 6.9)
Y
Y
Y
0000433
Oxygen
Insufficiency
related
Oxygen
Insufficiency
related
Umbilical UBA shall have umbilical gas, or gas
supply sensor (FMECA V6 Risk 6.5)
Y
Y
Y
0000430
Oxygen
Insufficiency
related
Oxygen usage to be monitored (FMECA V6
Risk 6.5)
Y
Y
Y
0000429
Oxygen
Insufficiency
related
Hard plastic knobs with a surface that is less Y
likely to move with friction shall be used on
oxygen cylinders(FMECA V6 Risk 6.2)
Y
Y
0000427
Oxygen
Insufficiency
related
Oxygen cylinder cannot be switched off prior to Y
the unit being switched on (FMECA V6 Risk
6.2)
Y
Y
0000425
Oxygen
Insufficiency
related
Diver shall be warned when hypoxic Make-UpGas is used(FMECA V6 Risk 6.1)
Y
Y
Y
0000424
Oxygen
Insufficiency
related
Diving with oxygen cylinders empty shall be
managed and avoided(FMECA V6 Risk 6.1)
Y
Y
Y
0000423
0000419
Cylinder related
Cylinder regulator O-ring shall be oxygen Y
compatible material (FMECA V6 Risk 5.7)
Y
Y
0000418
Cylinder related
Cylinder valve O-ring shall be oxygen Y
compatible material (FMECA V6 Risk 5.7)
Y
Y
Y
Cylinder related
The loss of gas from cylinder during dive Y
recovery action shall be in the user
manual(FMECA V6 Risk 5.6)
Y
0000417
0000416
Cylinder related
Cylinder valves compliance to ISO 10297- Y
2006(e) (FMECA V6 Risk 5.6)
Y
Y
0000415
Cylinder related
Cylinders shall be protected from detritus Y
(FMECA V6 Risk 5.5).
Y
Y
Y
Y
Cylinder related
Helium shall not be stored in the carbon Y
wrapped cylinders for a long periods (FMECA
V6 Risk 5.4)
0000414
Rev B2
Page 30 of 33