Download printable PDF

Transcript
Pololu Simple Motor Controller User’s Guide
© 2001–2015 Pololu Corporation
invalid after an amount of time equal to the Bad signal timeout has elapsed. Increasing this number makes your
settings more strict while decreasing it makes them more lenient.
Miscellaneous
The Disable safe start option disables Safe-start violation error, which is described in Section 3.4. In Serial/
USB input mode, this means that you will no longer have to send Exit Safe Start commands. In RC or Analog
input mode, this means that you will no longer have to center your inputs in order to restart the motor after an
error. This option makes it more likely that the motor will start when you are not expecting it.
The Ignore ERR line high option disables the ERR line high error, which is described in Section 3.4. This
allows your motor to run even if the ERR line is being driven high by some external device.
The Ignore pot disconnect option disables the disconnect detection for analog channels. Enabling this option
means that the device will stop toggling the positive (+) analog power pins in order to detect whether your
potentiometer is connected. The analog channel will still be considered invalid if the voltage goes out of the
acceptable range specified by the Error min and Error max parameters for that channel. This option is necessary
if you are connecting a limit switch or other device to the analog input in a way that prevents the disconnect
detection from working.
The Never sleep (ignore USB suspend) option prevents the device from going in to deep sleep mode in order
to comply with the suspend current requirements of the USB specifications. Checking this option will make the
device non-USB compliant, but will allow it to perform some functions while connected to a sleeping PC via
USB and the VIN power supply is disconnected. Note that the Simple Motor Controller can not drive a motor
while VIN is disconnected.
The Command timeout error occurs if you are controlling your motor using a microcontroller or a PC (Input
Mode is Serial/USB) and the Command Timeout period has elapsed with no valid serial or USB commands
being received by the controller. The default value of Command Timeout is 0, which means the error is
disabled. The Command Timeout can be specified with 0.01 s resolution and can be as high as 655.35 s. The
purpose of the Command timeout error is to ensure that your motor will stop if the software talking to the
controller crashes or if the communications link is broken. For more details about this error see Section 3.4.
5.4. Upgrading Firmware
The Simple Motor Controller has field-upgradeable firmware that can be easily updated when Pololu releases
bug fixes or new features.
Firmware Versions
• Version 1.00: This is the original version.
• Version 1.01: This version fixes a bug that made the ASCII Get Variable serial command malfunction
for negative numbers.
• Version 1.02: This version fixes a bug that caused the controller to detect the wrong baud rate if the baud
rate detection byte was sent during the first two milliseconds after a reset.
• Version 1.03, released on 2010-11-18: This version fixes a bug that caused the yellow LED to flicker
sometimes.
• Version 1.04, released on 2012-08-09: This version fixes some bugs with error handling. The effect of
the Exit Safe Start serial command now lasts for 200 ms instead of ending immediately and the ERR line
high error now works in RC and analog mode.
5. Configuring Your Motor Controller
Page 58 of 108