Appendix D: Robot Compatibility
Table 11-6 shows the commands used to configure the standard MagnaTran 6 compatibility for the MagnaTran 7 (Arm A and B Theta positions are 0° apart/servos hold
position at HALT).
Table 11-7: Standard MagnaTran 6 Compatibility
Parameter Type
Setting
Command to
SET
Command to
STORE
Command to
REQUEST
Communications
Protocol
RS-232
none (with Dip
Switch)
none
none
Serial Communications Mode
Monitor
SET COMM M/B
MON
STORE COMM
M/B
RQ COMM M/B
Command Flow
Mode
Sequential
SET COMM FLOW
SEQ
STORE COMM
FLOW
RQ COMM FLOW
Terminal Echo
Mode
ON
SET IO ECHO Y
STORE COMM
ECHO
RQ COMM ECHO
Linefeed After
Carriage Return
ON
SET COMM LF ON
STORE COMM LF
RQ COMM LF
Error Reporting
Level
2
SET COMM
ERRLVL 2
STORE COMM
ERRLVL
RQ COMM
ERRLVL
Data Reporting
REQ
SET COMM
DREP REQ
STORE COMM
DREP
RQ COMM DREP
Terminal Echo
Compatibility
MAG6
SET
COMPATIBILITY
ECHO MAG6
STORE
COMPATIBILITY
ECHO
RQ
COMPATIBILITY
ECHO
Theta Coordinate
Compatibility
MAG6
SET
COMPATIBILITY
COORDT MAG6
STORE
COMPATIBILITY
COORDT
RQ
COMPATIBILITY
COORDT
Theta coordinate system defines theta HOME for Arm A and Arm
B as 0°.
HALT Compatibility
MAG6
SET
COMPATIBILITY
HALT MAG6
STORE
COMPATIBILITY
HALT
RQ
COMPATIBILITY
HALT
Capture
Response Compatibility
MAG6
SET
COMPATIBILITY
CPTR MAG6
STORE
COMPATIBILITY
CPTR
RQ
COMPATIBILITY
CPTR
Wafer Speed
Compatibility
MAG6
SET
COMPATIBILITY
SPEED MAG6
STORE
COMPATIBILITY
SPEED
RQ
COMPATIBILITY
SPEED
Brooks Automation
Revision 2.2
11-15