PTU‐D300 E Series User Manual The PTU‐D300 uses high‐precision optical limit sensors that allow faster reset sequences and user‐programmable ranges. It can also be equipped with optional mechanical stops that will limit pan/tilt motion to preset limits. It is possible to set these stops to allow overlapping limits, as shown in the image on the previous page. Note: If needed for your application, order optional mechanical stops with your PTU‐
D300 because they are installed during manufacturing. 5.1.1 – Default Limits In the following image: 
The positive pan axis direction is clockwise when looking down at the top of the PTU‐D300. 
The positive tilt axis direction is clockwise when looking sideways at the PTU‐D300 with the motors and connectors facing to the right. Figure 4: Pan‐Tilt Default Factory Limits Note: The default pan axis user limits are +/‐ 168°. The default tilt axis limits are +30° and ‐90°. 28