Download S3100 User Manual.book
Transcript
S3100 User Manual Duplicate Master Detection The duplicate master detection problem occurs when two S3100 master units—with at least one using the SPCF mode—are using the same frequency channel and are seeing each other. More specifically, the problem is detected when the second S3100 is booting up. This bridge refuses to start its wireless operations (to prevent any interference with the working setup) and makes its three LEDs flash red (1-second intervals). In the CLI of the unit, the Current SPCF Connection Status parameter turns to Duplicate master detected (accessed through Advanced > Communication Status and Statistics > Wireless Status). Furthermore, an error message is logged in the unit. The already running master will not change its behavior. Finding a “Lost” S3100 Since the S3100 does not have a serial port, you may have difficulty accessing it if you do not remember its IP address or VSIP port. For instance, if you enabled security on the unit, you cannot access it with Telnet; if you lost its VSIP port, you cannot locate it with SConfigurator. To find a “lost” S3100 unit, you need to use SConfigurator and the common VSIP port. To find a lost S3100: 1. Open SConfigurator. 2. From the General tab, click Program Options. 3. Click Common to set the common VSIP port, then OK. 4. Click the Units tab. Verint Video Solutions 57