Download Aqwa User`s Manual
Transcript
Approach Line type: Stub For all sections other than tubular, only the inertias will be obtained automatically from the parameters that are entered in Design Modeler. If a stub element is not required, then it is possible to change it to a tubular line and define the diameter and thickness within the Aqwa Editor. There are options to change the diameter of a stub element in both the local Z and Y directions (Z Diameter, Y Diameter), as well as the Cross Section Area. For Aqwa, valid cross sectional areas vary between an ellipse and a rectangle with the width and height of the two diameters. In addition, you can specify a Viscous Drag Coefficient and Added Mass Coefficient in each of the Z and Y directions. It is also possible to define the mass contribution of the stub to the model (Mass/Unit Length). You cannot automatically add Discs to STUB objects, but you can add them manually if needed. 2.3.3. Point Mass Point mass elements can be inserted into the model; the properties can either be input manually or can be Program Controlled. If Mass definition is set to Manual, the point mass must have all its properties input by the user (Mass, X, Y, and Z coordinates). If a Program Controlled point mass is used, the mass and the horizontal position will be calculated from the panel elements in the structure (i.e. excluding tubular stub lines and point buoyancy bodies). The mass will equal the mass of water displaced, and the horizontal position will be that of the center of buoyancy. The moments of inertia (or radii of gyration) and vertical position (Z) cannot be determined by the program and must always be input. Moments of inertia can be defined directly or by inputting radii of gyration. If Define inertia values by is set to via Radius of Gyration, you need to enter Kxx, Kyy, and Kzz. If you select Direct input of Inertia, you must enter the Ixx, Iyy, and Izz values. Tip After inserting your point masses, solve for hydrostatics only; then the hydrostatic results will be available and the values of mass will be calculated before performing the full Aqwa analysis. 2.3.4. Point Buoyancy Point buoyancy (PBOY) elements can be inserted into the model; these require a position (X, Y, Z) and a Volume. 2.3.5. Disc Disc elements can be used to create an area that has drag (Viscous Drag Coef) and added mass (Added Mass Coef) in the direction perpendicular to the disc. The Diameter of the disc is required along with the centroid and the definition of the normal direction. If the centroid is at the position of an existing vertex, set Centroid Definition to Select Vertex and click Pick in the Vertex field; then select the vertex on the model and click Apply. To enter the coordinates of the vertex directly, set Centroid Definition to Specify Coordinates, and enter the X, Y, and Z values. You can specify the normal by picking a second vertex or specifying the direction of a normal vector. To use an existing vertex to define the normal, set Normal Definition to Select Second Vertex and click on Pick in the Normal Vertex field; then select the vertex on the model and click Apply. To enter the 12 Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information of ANSYS, Inc. and its subsidiaries and affiliates.