Troubleshooting
Problem
Possible
Causes
Suggested
Solutions
Line fuse does not blow,
but the motor does not
run (cont.)
5. Drive is in current
limit.
5. The red current limit
LED must be off. If
the red current limit
LED is on, verify that
the motor is not
jammed. It may be
necessary to
increase the TORQ.
LIMIT setting if it is
set to a value lower
than the current
rating of the motor.
6. Drive is not receiving
AC line voltage.
6. Apply AC line
voltage to L1 and L2.
7. Motor is not
connected.
7. Connect motor to A1
and A2.
1. MIN SPD and MAX
SPD not calibrated.
1. Calibrate MIN SPD
and MAX SPD .
Make sure settings
are not set too high.
2. Field output
connections are not
secure.
2. Check that the field
output connections
are secure if you are
using a shunt wound
motor
Motor runs too fast at
maximum speed setting