Download 4 - GE Intelligent Platforms: Support Home
Transcript
6 Read Request Command - 8322 The Read Request command is used to send an MMS Read message. This service supports all three scopes of the MMS read service. The COMM_REQ format of the Read Request is shown in the table below. ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁ Table 6-18. Read Request COMM_REQ Parameter Description Word Length of MDB Wait/NoWait Flag CRSW, Memory Type1 CRSW, Offset Idle Timeout Value Maximum Communication Time CommandNumber Association Control Block Pointer, Memory Type1 Association Control Block Pointer, Offset Invoke ID Data Type Data Type Size Variable Type Length of Variable Name or Address Variable Name or Address Alternate Access Index (only used if Variable Type 8-11) Number of Elements Variable Scope Length of Read Data Buffer Read Data Buffer, Memory Type1 Read Data Buffer, Offset1 Length of Domain Name Domain Name 1 Quick Reference: Memory Type %R %AI %AQ Decimal Value 8 10 12 Word Offset Value 0 1 2 3 4 5 6 7 8 9 - 10 11 12 13 14 15 - 30 31 - 32 49 0 (No Wait) See Footnote 1 0 - Max Configured 0 0 8322(2082H) See Footnote 1 33 34 35 36 37 38 39 - 54 See Table 6-20 See Table 6-54 1 to 2048 See Table 6-16 See Table 6-16 0 - 32 characterstring 0 - 65,535 See Table 6-19 See Table 6-19 See Table 6-20 1 - 32 or 1 - 16 0 or more %I %Q %T %M 70 72 74 76 Command Number - Identifies this as a Read Request command. Association Control Block - The PLC address of the Association Control Block for this association. Invoke ID - The unique MMS Invocation ID. Data Type - Specifies the expected type of the returned data for the read. If the data on the read response does not match this type, an error will be generated. Valid Data Type values are given in the table below. 6-28 MMS-Ethernet Communications for the Series 90-70 PLC User’s Manual - May 1994 GFK-0868