D. Troubleshooting Error code Description Error Warning Caused by Action 7664 Blue block temp high Yes Yes High temperature on blue DMD cooling block Check if air slots are free. Clean air filters. If problem persists, call a qualified service engineer 7663 Blue block temp open Yes Yes Temperature sensor on blue DMD cooling block not connected Call a qualified service engineer 7662 Blue block temp short Yes Yes Temperature sensor on blue DMD cooling block shorted Call a qualified service engineer 7660 Engine air temp high Yes Yes High temperature on engine Check if air slots are free. Clean air filters. If problem persists, call a qualified service engineer 7659 Engine air temp open Yes Yes Temperature sensor on engine not connected Call a qualified service engineer 7658 Engine air temp short Yes Yes Temperature sensor on engine shorted Call a qualified service engineer 7999 Fan speed cathode too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7998 Fan speed cathode high - Yes 7997 Fan speed anode too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7996 Fan speed anode high - Yes 7995 Fan speed engine too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7994 Fan speed engine high - Yes 7993 Fan speed cold mirror too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7992 Fan speed cold mirror high 7991 Fan speed heat ex. too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7990 Fan speed heat ex. high - Yes 7989 Fan speed smps 1 too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7987 Fan speed smps 2 too low Yes Yes fan is running too slow or not at all If problem persists, call a qualified service engineer 7985 Red DMD temp low No Yes low temperature on dmd turning on the lamp will heat up the dmd 7984 Red DMD temp high Yes Yes high temperature on dmd check if air slot are free; clean air filters If problem persists, call a qualified service engineer 7983 Green DMD temp low No Yes low temperature on dmd turning on the lamp will heat up the dmd 7982 Green DMD temp high Yes Yes high temperature on dmd check if air slot are free; clean air filters If problem persists, call a qualified service engineer 7981 214 Blue DMD temp low No Yes low temperature on dmd turning on the lamp will heat up the dmd R5976986 FLM HD18 15/03/2010