Download TYPHOON - Electrostatica
Transcript
9. Faults Warning: Disconnect the power supply before carrying out work on the unit. 9.1. Air knife fault Problem No air from air knife. Air knife has insufficient blowing power. Cause Blower does not run Air slot is fouled. Air filter on blower is fouled. Blower operating in wrong direction Solution See blower instructions. Remove contamination (see Maintenance). Clean or replace the filter. Change direction of rotation of blower. Table 1 air knife faults 9.2. EP-Sh-N anti-static bar fault Problem No or poor ionisation. No high voltage on emitter points Cause No high voltage. Anti-static bar is fouled. Emitter points are damaged. High voltage power unit is defective. Short circuit in the HV cable or anti-static bar. Solution Restore high voltage. Clean anti-static bar. Return air knife for repair. Repair high voltage power unit. Eliminate short circuit or return the bar for repair. Table 2 EP-Sh-N bar faults 9.3. P-Sh-N-Ex anti-static bar fault Problem No or poor ionisation. No high voltage on emitter points. Cause No high voltage. Anti-static bar is fouled. Emitter points are damaged. No mains voltage. External fuse is defective. Transformer is defective. Solution See P-Sh-N-Ex anti-static bar manual Clean anti-static bar. Return air knife for repair. Restore mains voltage. Replace the fuse. Replace the bar. Table 3 P-Sh-N-Ex bar faults Typhoon_UM_9752902012_GB_V2_1 11