VACC MIN and VACC MAX are values programmable by the "Program Vacc" function. 13) ADJUSTMENT#1 BDI It adjusts the upper level of the battery discharge table. 14) ADJUSTMENT#2 BDI It adjusts the lower level of the battery discharge table. 15) MAIN CONT. VOLTAGE This parameters adjusts the Line contactor coil voltage (PWM output C26). 16) AUX OUTPUT VOLTAGE This parameters adjusts the Electric brake coil voltage (PWM output C28). 17) LOAD HM FROM MDI When set On, the HourMeter of the Controller is transferred and recorded on the HourMeter of the Standard MDI (connected on the Serial Link). 18) CHECK UP DONE Turn it ON when the required Maintenance service has been executed to cancel the CHECK UP NEEDED warning. 19) CHECK UP TYPE It specifies the handling of the CHECK UP NEEDED warning: - NONE: No CHECK UP NEEDED warning. - OPTION #1: CHECK UP NEENED warning shown on the hand set and MDI after 300 hours. - OPTION #2: Equal to OPTION#1 but speed reduction after 340 hours. AE9ZP0BC - DUALAC2/&HP/POWER - User Manual Page - 51/89