User Manual for LEVIFLOW LFS Flowmeters
www.levitronix.com
3.2 Installation of Converter LFC-6C
3.2.1 Overview and Preparation
b
a
Fixation Bars
Converter
Termination
Box
Connector
Box
Fixation
Bar
Multi-Converter
Array
Sensor Connectors
c
Channel
Indication
d
Channel 6
Pin 1
DIN Rail Mounting
Re-Zero
Button
LOW ADRS
Channel
Selection
High ADRS
4 Digit Display
Figure 11: 6-channel controller LFC-6C
1. Check if all parts are delivered as shown in Figure 11. For every configuration (single
converter as shown in Figure 11a and multi converter array as in Figure 11b) a termination
box (resistance to terminate the RS485) and a connector box (wiring) is needed.
2. For communication with RS485 check the address settings of the potentiometers on the front
panel of the converter (see Figure 11d). The total address of the first channel is:
“High ADRS” x 10 + “Low ADRS” x 1
TM
3. The LEVIFLOW Configuration Software can be used to debug and configure the flowmeter
over the RS485. For communication with RS485 the MODBUS protocol can be requested at
Levitronix.
PL-4502-00, Rev05, DCO# 11-131
13