4I23 USER'S MANUAL
OPERATION
RS-422 OPERATION
When RS-422 levels are used, the DCD, DSR, and RI (Data Carrier Detect, Data Set Ready, and
Ring Indicator) input lines on each channel are not used. The DCD and DSR lines will be in the active
state, and the RI line will be in the inactive state.
RS-485 OPERATION
The 4I23 can optionally be supplied with RS-485 capable driver and receiver chips. These chips
have a wider operational common mode range than the RS-422 chips normally supplied. RS-485
drivers are also designed to not interfere with RS-485 bus operation when powered down. Because of
these differences, RS-485 driver chips are more expensive than the RS-422 chips normally used.
Contact MESA if you need the 4I23 supplied with RS-485 chips.
To connect the 4I23 to an RS-485 bus, you need to connect RXDA to TXDA and RXDB to
TXDB. The RS485 I/O pair is then connected to TXDA and TXDB.
Page 19