Transcript
Section-9 9.1.3 Generator ON Facilities The Generator ON facility must use a normally open contact that closes to indicate that a generator is running and supplying input power to UPS. It is located at the bottom of the DPA UPSCALE TM frame on communication card with terminal blocks X1 …X2. See section 3 / 1.2.1 for details When used, this facility disables the UPS static bypass and prevents the UPS from transferring the load onto the generator power supply. Generator alarm panel X1 X1/1 X1/2 X2 UPS Generator port X1 Figure 1.3: Generator ON Connection 9.1.4 Wavemon Shutdown and ManagementSoftware 9.1.4.1 Why is UPS Management important? By combining a UPS with network management products, such as an SNMP protocol, System-administrators are guaranteed their data and their system will constantly be protected from corruption or data loss even in the event of an extended power failure or when batteries reach a critical low state. In the event of a power disturbance system administrators can also monitor their network from a central location, allowing an early detection of problems. In fact utility power is unreliable at times, ensuring that all network systems have constant power can be a difficult task. The situation becomes even more complex if systems are managed across a Local Area Network (LAN) or Wide Area Network (WAN) around the world. When a power failure occurs action can be taken to protect the system and its valuable data. If no action is initiated by the operator, this event can seriously damage the system. The UPS software will react automatically in such a case and shutdown the operating system. NEWAVE has found it important to have a complete solution for its UPS and is able to offer a wide range of monitoring/remote controls for assuring the maximum protection degree to the NEWAVE customers. 9.1.4.2 WAVEMON Shutdown and Monitoring Software WAVEMON Software is an external monitoring and shutdown software which was designed to operate with all NEWAVE UPS products, both with the DRY PORT (Relays) on Terminal block X1 and RS232 port JD1 on the communication card The software packet consists of a CD ROM for most diffused operating systems (Windows, Unix, OS/2, DEC VMS, Novell, Apple), a standard connection and a user manual. The dry port X2…X4 with voltage-free contacts may also be used for automatic shutdown in connection with WAVEMON Software. It is necessary to provide a cable of 0.5 mm2 to connect Terminals X1 of the UPS and the serial port of the server. 04-0314_S9_NEUT_OPM_UPSCALE_ST_GB_091101.doc Printed in Switzerland – Modifications reserved Page 3/8