VLT®AutomationDrive Instruction Manual Installation FC PLC 2 2 PE PE PE PE Min. 16 mm² - Equalizing cable 130BB922.10 an equalizing cable next to the control cable. Minimum cable cross-section: 16 mm2. 130BB609.11 PE FC PE 100nF FC FC 69 68 61 PE PE PE PE Min. 16 mm² - Equalizing cable 130BB923.10 Avoid EMC noise on serial communication This terminal is grounded via an internal RC link. Use twisted-pair cables to reduce interference between conductors. The recommended method is shown below: 69 68 61 FC 68 69 PE PE PE PE Min. 16 mm² - Equalizing cable 130BB924.10 FC 2.4.5.6 Jumper Terminals 12 and 27 • Digital input terminal 27 is designed to receive an 24V DC external interlock command. In many applications, the user wires an external interlock device to terminal 27. • When no interlock device is used, wire a jumper between control terminal 12 (recommended) or 13 to terminal 27. This provides an internal 24V signal on terminal 27 • No signal present prevents the unit from operating. • When the status line at the bottom of the LCP reads AUTO REMOTE COAST, this indicates that the unit is ready to operate but is missing an input signal on terminal 27. • When factory installed optional equipment is wired to terminal 27, do not remove that wiring. 2.4.5.7 Terminal 53 and 54 Switches Alternatively, the connection to terminal 61 can be omitted: 69 68 • Analog input terminals 53 and 54 can select either voltage (-10–10V) or current (0/4–20mA) input signals • Remove power to the Adjustable frequency drive before changing switch positions • Set switches A53 and A54 to select the signal type. U selects voltage, I selects current. • The switches are accessible when the LCP has been removed (see Figure 2.14). Note that some option cards available for the unit may cover these switches and must be removed to change switch settings. Always remove power to the unit before removing option cards. • Terminal 53 default is for a speed reference signal in open-loop set in 16-61 Terminal 53 Switch Setting • Terminal 54 default is for a feedback signal in closed-loop set in 16-63 Terminal 54 Switch Setting 2.4.5.5 Control Terminal Functions Adjustable frequency drive functions are commanded by receiving control input signals. • • 2-10 The default terminal programming is intended to initiate Adjustable frequency drive functioning in a typical operational mode. A jumper wire may be required between terminal 12 (or 13) and terminal 27 for the Adjustable frequency drive to operate when using factory default programming values. 50/60Hz ground loops With very long control cables, ground loops may occur. To eliminate ground loops, connect one end of the shield-toground with a 100nF capacitor (keeping leads short). PLC • Each terminal must be programmed for the function it will be supporting in the parameters associated with that terminal. SeeTable 2.3 for terminals and associated parameters. It is important to confirm that the control terminal is programmed for the correct function. See 4 User Interface for details on accessing parameters and 5 About Adjustable Frequency Drive Programming for details on programming. MG.33.AI.22 - VLT® is a registered Danfoss trademark