Download 5 DDEC FEATURES - Wanderlodge Gurus
Transcript
DDEC IV APPLICATION AND INSTALLATION MANUAL 5.1 AIR COMPRESSOR CONTROL Air Compressor Controlis an optional DDEC feature that allows DDEC to regulate engine speed and load/unload a valve in order to maintain a requested compressor outlet air pressure for air compressor applications. The DDEC Air Compressor Control Feature is available with the following software releases: DDEC III - Release 4.0 (only) DDEC IV - all software versions (Release 20.0 or later) 5.1.1 OPERATION The ECM monitors the air outlet pressure while varying the engine speed and operating load/unload a valve. The valve will be opened or closed. The desired operating pressure may be varied by the operator, within limits preset by the OEM. The ECM will activate the Air Compressor Governor Controls when the digital input “Air Compressor Load Switch” is grounded. Engine speed is governed based on the actual air compressor outlet pressure versus the desired output pressure. The Air Compressor Pressure Sensor provides a pressure signal to the ECM. The engine response to various pressure conditions is listed in Table 5-1. Result Pressure Set Point Current outlet pressure is below the pressure set point Pressure in the system continues to increase and a threshold pressure is exceeded Current outlet pressure is above the pressure set point Engine speed increases as required up to PTO maximum speed* The air compressor solenoid digital output is enabled† (opened) Engine speed decreases as required down to the minimum PTO speed. * The engine will continue to run at PTO maximumuntil the outlet pressure matches the sensor pressure. † DDEC will open and close the loading valve as a function of pressure with hysteresis. When the pressure reaches a programmable limit above the pressure set point the DDEC digital output will be grounded. This output may be used to either open an air compressor vent or close the air inlet. Once the air pressure has dropped to a lower programmable limit, the digital output will be open circuited which will either close the vent Table 5-1 Engine Operation with Air Compressor Controls Each horsepower rating has an associated pressure range. Horsepower ratings are defined at time of order entry. The minimum and maximum pressure setting for each of the horsepower curves is set with the DDDL/DDR, Vehicle Electronic Programming System (VEPS), or DRS. The initial pressure set point is saved between ignition cycles. Increase (Resume/Acceleration On) Momentarily toggling and releasing the Increase Switch (grounding the "Resume/Acceleration On" digital input) increases set point pressure by 4% of the pressure range. Holding the switch in the increase position (grounding the digital input), will increase the set point pressure at a rate of two increments per second. Releasing the switch sets the compressor controls to the higher setting. All information subject to change without notice. (Rev. (Rev. 3/02)) 7SA742 0203 Copyright © 2002 DETROIT DIESEL CORPORATION 5-3