12.6 Calculation of Paired Trap Agreement. Calculate the relative deviation
(RD) between the Hg concentrations measured with the paired sorbent traps using
Equation 30B-5.
RD =
C a − Cb
C a + Cb
× 100
Eq. 30B-5
12.7 Calculation of Measured Spike Hg Concentration (Field Recovery Test).
Calculate the measured spike concentration using Equation 30B-6.
C rec =
m s mu
−
vs
vu
Eq. 30B-6
Then calculate the spiked Hg recovery, R, using Equation 30B-7.
R=
C rec × v s
× 100
m spiked
Eq. 30B-7
13.0 Method Performance
How do I validate my data? Measurement data are validated using initial, one-
time laboratory tests coupled with test program-specific tests and procedures. The
analytical matrix interference test and the Hg0 and HgCl2 analytical bias test described in
Section 8.2 are used to verify the appropriateness of the selected analytical approach(es)
as well as define the valid working ranges for sample analysis. The field recovery test
serves to verify the performance of the combined sampling and analysis as applied for
each test program. Field test samples are validated by meeting the above requirements as
36