Download Operation Manual - SPX Corporation
Transcript
Section 5 – Depth and current readings 5.1 Depth readings The RD7000+ can measure the depth of buried conductors down to depths of approximately 6 meters (20 feet) for a line, or 15 meters (50 feet) when using a sonde. RD7000+ will locate to greater depths but accuracy may be reduced. The depth measurement is to the center of the pipe or cable. The best readings are detected from signals outputted by a transmitter rather than from passive sources. The RD7000+ is capable of determining depth when locating passive power signals. However passive signals on lines are less suited for measuring depth because accuracy is questionable due to the passive signal being present on more than one line. To avoid signal distortion, do not apply the signal by induction. If direct connection or signal clamping is not possible, place the transmitter at least 15 meters from the point of any depth measurements. Depth measurements are not accurate if there is audible interference or if part of the transmitter signal has coupled to a nearby line. Confirming the peak position coincides with a null position indicates that the position is suitable for making a depth estimate. Figure 5.2: Depth readings NOTE: The accuracy of depth measurement is subject to a number of factors and is meant as a guide only. Exercise caution when performing any excavation. WARNING! Do not make depth measurements near bends or tees in the line. Go at least 5 meters from a bend for best accuracy. 5.1.1 TruDepth and Compass It is important to note that the RD7000+ will only display depth when the locator is correctly oriented above the target line, cable or sonde. To ensure the locator is correctly oriented, use the LCD Compass: When locating lines, make sure the Compass displays the line in the 6 o’clock position. When locating sondes (see Section 10.4), make sure the Compass displays the line in the East / West position. Figure 5.1: Taking a depth reading 16 RD7000+ Operation Manual • Pinpoint the target line accurately with the locator. • Check the locator is directly over the line, the antennae are at right angles to it and the locator is vertical. Adjust sensitivity level to bring the bar graph indication on scale. • Press the depth button to toggle between depth and current readings. If the ground appears to radiate a strong field, perhaps near a radio station, check depth by holding the bottom of the antenna 50mm above the ground and subtract this reading from the indicated depth.