Download TeeJet 844E Manual
Transcript
844-E Sprayer Control Condition 3. Flow meter turbine symbol Possible Cause Solution A. Stalled Flow meter Make sure there is no pressure in the system. continually flashes on/off Remove the flow meter from the discharge line. Inspect the inside of the meter for obstructions. The turbine should move freely. If it does not rotate easily, try flushing it out with clean water. If it remains stuck, remove the turbine by releasing the retaining clip. Clean the turbine carefully and make sure it rotates. Replace the turbine into the flow meter body and secure with the retaining clip. If you have a rapid check flow meter, remove the turbine from the flow meter body by unthreading it at the sensor. Check the turbine for obstructions. Flush with clean water or disassemble if necessary. Check to ensure that the sprayer pump has been engaged while trying to spray. Check cabling for any loose connections. 4. Rate oscillation A. Extreme low regulated flow Due to very low application rates (GPA, G/1000 ft2), (l/Ha) the regulating valve in throttling mode is operating in an almost closed position. Adjust the Reg. Valve Speed Number in the System Setup Mode (page 17) to a slower value. Plumb the regulating valve in bypass mode. This should allow the regulating valve to operate more in the center of its rotation. If you change from throttling mode to bypass mode, you must reprogram the Pressure Regulating Mode in the System Setup mode. Refer to page 16 of the 844 Installation Manual. 5. Sprayer stops spraying while in Auto Mode. A. Pressure Regulating Mode is programmed incorrectly B. Flow meter stalled Check the Pressure Regulating Mode in the System Setup mode of the 844. Refer to page 16 of the 844 Installation manual to insure that the controller has been correctly programmed for the regulating valve position on your sprayer. A flashing turbine symbol will also indicate if the flow meter has stalled. Inspect flow meter for obstructions. If flow meter turbine is impaired, clean and replace. Sometimes when the regulating valve closes too far, maybe even complete shut-off (with ball type regulating valves), this can cause the flow meter to stall and no flow or pressure regulation will occur. Press the Auto/Manual key so that the LED indicates “MAN” mode, depress the Plus key for approximately three (3) seconds. You should see the tips begin to spray. Press the Auto/Manual key so that the LED indicates “Auto” mode, and continue to spray. 98-70006-ENUS R4 27