Download MARC & MARC E Series

Transcript
Intelix MARC E User Manual
ReO Bus Modes
8.2.1 Remote blink codes
The LEDs on remotes have five main blink codes to assist determining the state of a remote (these
codes appear only on the physical remotes, not on the PC screen):
a) All LEDs off: either not powered or normal run state; if new system check power
supply to remote.
b) Single blink: powered but no communication. ReO data bus problem or not yet
exercised. If new system, there is a problem in the ReO bus to that remote.
c) Double blink: powered up and received a message from the matrix.
d) Triple blink: This state means a message has been lost between the matrix and the
remote. ReO bus problem. Check for noise or reflection conditions on the bus.
e) Steady on: custom programmed state, unknown meaning.
Remember:For correct operation of the system, you must go to Run mode after all
modifications are complete.
57