Step 3: Place the threaded bolts on the Connecting Plate (D) into the elongated holes on the Spring Brackets (A) and (F) in position shown. Secure the holder loosely using two M4 hexagon Nuts (C) as shown in Figure 3. Step 4: Adjust the Spring Brackets (A) and (F) suitably before using the scanner. Temporally place the hand-held scanner into the mounted holder and fasten the two M4 hexagon Nut (C). Torque to 18 lbf-in. Remove the hand-held scanner from the holder. Figure 3 Step 5: Next attach the holder to the 8580/90 terminal (G) as shown in Figure 4-1 or 4-2 * and Flat Washer (H), through the Angle Bracket (B) into Vehicle Mount Terminal (G). Torque to 26 lbf-in. * For assembly with RAM mount use M8 x 12 mm Screw (I), see Figure 4-1. * For assembly with Standard Mount (J) use M8 x 16 mm Screw (K), see Figure 4-2. Figure 4-1 Figure 4-2 Part No. 1616310 Revision A Sheet 2 of 4