Download Installation Instruction for MT3601

Transcript
Step 3: Place the threaded bolts
on the Connecting Plate (D) into
the elongated holes on the Spring
Brackets (A) and (F) in position
shown. Secure the holder loosely
using two M4 hexagon Nuts (C)
as shown in Figure 3.
Step 4: Adjust the Spring
Brackets (A) and (F) suitably
before using the scanner.
Temporally place the hand-held
scanner into the mounted holder
and fasten the two M4 hexagon
Nut (C). Torque to 18 lbf-in.
Remove the hand-held scanner
from the holder.
Figure 3
Step 5: Next attach the holder to the 8580/90 terminal (G) as shown in Figure 4-1 or 4-2 * and Flat
Washer (H), through the Angle Bracket (B) into Vehicle Mount Terminal (G). Torque to 26 lbf-in.
* For assembly with RAM mount use M8 x 12 mm Screw (I), see Figure 4-1.
* For assembly with Standard Mount (J) use M8 x 16 mm Screw (K), see Figure 4-2.
Figure 4-1
Figure 4-2
Part No. 1616310 Revision A
Sheet 2 of 4