SPI Devices and Support
Single Cycle
When counting pulses, the counter will stop counting in
either direction if the count goes larger (or smaller) than the
standard integer (32 bit). A Reset or Load is required to restart
counting.
Range Limit
Counting range is limited between zero (0) and the PD (DTR)
input on the CNTR_LS7366R function block. The LD function
block input must be used to load the DTR (one scan cycle).
Modulo N
The counter value will be equal to the value of the input signal
divided by the value loaded in DTR, plus 1 (DTR+1). If DTR is
1, then the count will equal the input signal divided by 2 or will
count at 1/2 the rate of the input signal.
Index Mode: Disable Index
The device’s Index input will have no affect on operation.
Load CNTR
Configures the device’s Index input to act as a load counter.
This will load the value of the function block input PD (DTR) as
the actual count.
Reset CNTR
Configures the device’s Index input to act as a reset counter.
This will reset the actual counter to zero.
Load OTR
Configures the devices Index input to transfer the actual count
into the OTR register. The OTR register is a temporary register
for storing the count.
Asynchronous Index
Asynchronous index mode. Valid in all modes.
Synchronous Index
Synchronous index mode. Only valid in quadrature mode.