Download User Manual

Transcript
flowcom Manual Concept
1.3
Page 2
Additional Firmware Options
1.3.1 gas
1.3.1.1 Extensive Compressibility Tables
In addition to „normal” gas compensation calculations according to the inaccurate perfect gas law, flowcom also
contains compressibility data for numerous gases and can deliver correct readings even at higher pressures or
lower temperatures. This stored information is so extensive that it includes practically all technically relevant
pressure and temperature variables.
1.3.1.2 GERG88 Natural Gas Calculation Standard
If you are measuring natural gas, flowcom is the natural choice for you. flowcom contains the condition formulas
according to GERG88, which is the standard for large European gas providers such as British Gas and Ruhrgas.
This method of calculating natural gas compressibility was developed by European gas providers for balancing
purposes and is now being instituted by them as an industry standard. GERG88 replaced the then-valid, though
fairly inaccurate AGA NX19 calculation standard. With flowcom you are on the cutting edge of the technology.
1.3.1.3 Programmable Compressibility Table
Even if you are not using natural gas or one of the other pre-programmed gases, flowcom still has the right
answer. Though you can always make calculations based on the perfect gas law, if you know the compressibility
of your medium you can program your own compressibility table. flowcom will then report the exact condition of
your gas in the pressure and temperature ranges that are relevant to your application.
1.3.2 energy
1.3.2.1 Extensive Density and Enthalpy Tables
flowcom contains data, not only for the density, but also for the enthalpy of water, saturated steam, and steam.
Therefore, the process data is not developed from erroneous models, but rather from extensive tables, ensuring
superb precision in the calculation of your process data.
1.3.2.2 Programmable Tables
Even if your medium is not water or steam, flowcom is still the right answer. You can always make calculations
based on constant heat capacity, or, if you know the enthalpy of your medium, you can program your own
enthalpy and density table. flowcom will then deliver the exact condition of your medium within the pressure and
temperature ranges applicable to your operation. You can, for instance, meter the refrigeration energy of
ammonia in all its aggregate states.
1.4
Additional Hardware Options
Hardware versions basic and basic+a2 can only measure one channel each, due to their hardware equipment.
They do not dispose of the options described below. With hardware versions basic+a1 and high end you can
measure either two independent channels or the versions described below.
Exception: in model versions basic and basic+a2, the heading „Feed/Return System with One Channel” also
applies to energy and energy2.
1.4.1 gas, energy and energy2
The following measurements can be conducted for gas as well as for energy and energy2.
1.4.1.1 Redundant Measurement
flowcom allows you to take a redundant (i.e. dual) reading in one pipe. Each channel monitors the other, and if
the results do not agree – or if one measurement disappears – an alarm will be given. This gives you a high
degree of extra security for your „critical” site.
Technical information subject to modification.
Current version: July 2005